Ordinance No. 733ORDINANCE NO . 7 33 AN ORDINANCE A!LIENDING AN ORDINANCE, "AN ORDINANCE PROVIDING FOR FIRE LIMITS AND REGULATIONS GOVERN- ING THE CONSTRUCTION, ALTE:RHTION, EQUIPMENT AND REMOVAL OF BUILDINGS f;ND STRUCTURES WITHIN THE CITY LIMITS OF BAYTOWN, TEXAS; REPEALING ORDINANCES IN- CONSISTENT HEREWITH; CONTAINING A SAVINGS CLAUSE; PROVIDING A PENALTY AND THE EFFECTIVE DATE THEREOF." BEING ORDINANCE NO. 637, PASSED BY THE CITY COUNCIL OF THE CITY OF BJAYTOWN ON THE 10TH DAY OF OCTOBER, 1961, BY AMENDING SECTION 15 AND ADDING SUBPARA- GRAPHS - SECTIONS 15 -1 GENERAL, 15 -2 COLUMNS AND PIERS, 15 -3 FLOORS, 15 -4 ROOFS, 15 - -5 BEALIS, GIRDERS AND TRUSSES, 15 -6 ll;ULS, 15 -7 FLOORING, INTERIOR FINISH SUPPORTS AND TRIM, SECTION 15A UNPROTECTED NONCOi;iBUST- ISLE. CONSTRUCTION, SECTIONS G�:NERAL, 15A -2 EX- TERIOR ti- JALLS, 15A -3 ROOFS AND 15A -4 PARTITIONS; AND PROVIDING FOR THE PUBLIC. =;TION AND EFFECTIVE DATE THEREOF. BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF BAYTOILlN: Section 1: That Section 15, Fireproof, Semi- Fireproof and Heavy Timber Construction, of said Ordinance No, 637, shall be amended to read as follows: FOR FIRE ZONE NO. ONE Section 15: FIRE -- RESISTIVE CONSTRUCTION - TYPE A Section 15 -1: General: (a) All structural members including walls, columns, piers, beams, girders, trusses, floors and roofs shall be of approved non - combustible material. (b) No pipes, wi-es, cables, ducts or other service equipment shall be embedded in the -required fireproofing of any structural member, nor shall they be between the required fireproofing and the structural member protected; however, this bhall not prohibit the installation of service equipment between fire resisting ceilings and the structural members pro- tected thereby as covered by Section 15 -8. Section 15 -2: Columns and Piers: (a) Columns and piers supporting loads from only one floor or roof shall have a fire resistance rating of not less than three (3) hours. Columns and piers supporting loads from more than one floor or roof shall have a fire resistance rating of not less than four (4) hours. all spaces between the required fireproofing and the member protected shall be fire - stopped with noncombustible material at each floor level. (b) Where the fireproofing of columns is subject to damage from moving vehicles, handling of merchandise or other sources, the fireproof- ing shall be protected against such possible damage. Section 15 -3: Floors: Floors shall have a fire resistance rating of not less than three (3) hours. Section 15 -4: Roofs: Roofs shall have a fire resistance rating of not less than two (2) hours. �1 Section 15 -5: Beams, Girders and Trusses: (a) Girders and trusses supporting loads from only one floor or roof shall have a fire resistance rating of not less than three (3) hours. Girders and trusses supporting loads from more than one floor or roof shall be individually protected to have a fire resistance rating of not less than four (4) hours. Section 15--6: Walls: (a) Bearing portions of exterior and interior walls shall have a fire resistance rating of not less than four (4) hours. (b) Nonbearing portions of exterior and interior walls shall be of approved noncombustible material and: (1) '�Jhere a horizontal separation of five (51) feet or less is provided, nonbearing portions of exterior walls shall have a fire resistance rating of not less than three (3) hours and the total area of windows in such portions of an exterior wall shall not exceed forty (40;0) percent of the total wall area; (2) 'Jhere a horizontal separation of more than five (51) feet but less than twenty (201) feet is provided, non- bearing portions of exterior walls shall have a fire re- sistance rating of not less than two (2) hours and the total area of windows in such portions of an exterior wall shall not exceed forty (40;x) percent of the total wall area; (3) ':!here a horizontal separation of twenty (201) feet to thirty (301) feet is provided, nonbearing portions of exterior walls shall have a fire resistance rating of not less than one (1) hour and the total area of windows in such portions of an exterior wall shall not exceed sixty (60,x) percent of the total wall area; (4) tlhere a horizontal separation of thirty (301) feet or more is provided, no fire resistance rating is re- quired for the nonbearing portions of exterior walls; (5) Openings in exterior ".walls shall be protected in accordance with section `1 and vertical separation between openings in exterior walls shall be provided in accordance with section -.-2, t_ t,�, j �Z (c) Lintels over openings in walls shall have a fire resistance rating not less than required by this section for the wall in which the lintel is placed; however, no fire resistance rating shall be required when the opening is spanned by a masonry arch designed to carry all im- posed loads or the opening is spanned by a beam above the lintel which has a fire resistance rating not less than required by this section for the wall in which the beam is placed, or the span does not exceed four (4 ") feet. Stone lintels shall not be used unless supplemented with iron or steel lintels or masonry arches designed to support the imposed loads. Section 15 -7: Partitions: In buildings four (4) stories or more in height, interior parti- tions enclosing elevator shafts, stairways required by section 14, ordin- ance No. 637, and other openings through floors shall be of approved non- combustible material and shall have a fire resistance rating of not less than two (2) hours. In buildings less than four (4) stories in height, partitions enclosing elevator shafts, stairways - required by sections _3 and other openings through floors shall be of approved non- combustible material and shall have a fire resistance rating of not less than one (1) hour. all other permanent partitions shall be of approved noncombustible material except the doors, door casings, frames, jambs and bucks, window and transom frames and casings may be of wood. Section 15 -8: Fire Resisting Ceilings: (a) Fire resisting ceilings shall be continuous except that one electrical outlet box not exceeding sixteen (16) square inches in area may be installed in such ceilings in each ninety (90) square feet of ceiling area. Noncombustible pipes, ducts, additional or larger elect- rical outlets and other service equipment may be installed in fire re- sisting ceilings only when the type of ceiling to be used has been tested with such equipment installed in place and the proportionate area of openings for such equipment to be installed in the ceiling does not ex- ceed the proportionate area of such openings in the assembly tested,and no opening is larger than that in the assembly tested. (b) Duct openings installed in accordance with paragraph (a) a- bove shall be protected by approved fire dampers. (c) Nothing in this section shall be construed to prevent open- ings in fire resisting ceilings into shafts or ducts, the enclosing walls of which are of construction equivalent to the ceiling. (d) The space above fire resisting ceilings shall be firestopped with approved noncombustible material to form areas of not more than fifteen hundred (1500) square feet. Steel not thinner than 24 gauge shall be accepted as firestopping. Section 15 -9: Flooring, Interior Finish Supports and Trim: (a) Uhere the floor finish is not laid directly on the floor slab the space between the floor finish and the slab shall be filled with non- combustible material in such a manner that there will be no open spaces under the floor finish which will exceed one hundred (100) square feet in area. Combustible boards not more than one -half (1/211) inch thick may be placed under the floor finish if laid directly on the floor slab or firestopped as required for the floor finish. (b) 'Jooden trim used for door or window casings, chair rails, pic- ture mouldings and baseboards shall be backed solidly with noncombustible material. (c) Supporting members for wall or ceiling finish shall be of non- combustible material except for furring strips applied directly against a noncombustible surface, FOR FIRE ZONE NO , TIvIO Section 15A: UNPROTECTED NONCOMBUSTIBLE CONSTRUCTION: Section 15A -1: General- All structural members, including walls, partitions, columns, piers, beams, girders, joists, trusses, floors and roofs shall be of approved noncombustible material, and: Section 15A -2: Exterior Walls: (a) Exterior walls shall be of approved noncombustible material (1) !:!here a building exceeds thirty five hundred (3,500) square feet in area and a horizontal separation of less than twenty (201) feet is provided exterior walls shall have a fare resistance rating of not less than two (2) hours and the total area of windows in such walls shall not exceed forty (40,x) percent of the wall area, (2) !there a building exceeds thirty five hundred (3,500) square feet in area and a horizontal separation of twenty (201) feet to thirty (301) feet is provided exterior walls shall have a fire resistance rating of not less than one (1) hour and the total area of windows in such walls shall not exceed sixty (60 ')) percent of the wall area; (3) Where the building is 1; ss�' than thirty five hundred � (3,500) square feet in area horizontal separation of thirty (301) feet or more is provided, no fire resistance rating is required for exterior walls. (b) Exterior enclosure weatherproof exterior. Section 15A -3: Roofs: Roofs of unsprinkled bu square feet in area shall not applied directly to its upper pagation of fire on the under walls shall provide a durable and stable ildings exceeding nine thousand (9,000) have a metal roof deck with any material surface which presents the hazard of pro - side of the metal roof deck. Section 15A -4: Partitions: Permanent partitions shall be of approved noncombustible material, and shall have a fire resistance rating of not less than one (1) hour when enclosing elevator shafts, stairways required by section 14 (ordin- ance number 637) and other openings through floors. Doors, door casings, frames, jambs and bucks, window and transom frames and casings may be of wood. Section 2: That all the terms and provisions of the said Ordinance No. 637, passed by the City Council of the City of Baytown on the 10th day of October, 1961, are hereby continued in full force and effect and any person violating any of the terms of the ordinance shall be subject to the penalties provided therein. Section 3: Effective Date: This ordinance shall take effect from and after ten 10) days from its passage by the City Council. The City Clerk is hereby directed to give notice hereof by causing the caption of this ordinance to be published in the official newspaper of the City of Baytown at least twice prior to the effective date. INTRODUCED, READ and PASSED by the affirmative vote of a majority of the City Council of the City of Baytown on this the / day oft4ti� -, 1� 1964. L. Liggett, Ivi.D., Mayor ATTEST: Edna Oliver, City :clerk APPROVED: ka-il George Chandler, City Attorney